Index wersja polska wersja polska

Serial and printer interface for the FX-602P calculator

This device attempts to emulate the original FA-2 cassette interface and the FP-10 printer. Files are transferred through the serial port instead of the tape. It's based on the FX-700P mass storage and printer interface with software version 27, and uses the same data format.

An optional parallel printer port board can be connected to the I2C bus. All known print modes of the FX-702P and some print modes of the FX-602P are supported.

Hardware

schematic of the FX-602P interface

The jumpers on the PB5 and PB6 pins can disable the tape or printer support.

Jumper on PB5 Jumper on PB6 Selected function
openopen Both tape and printer support enabled.
openclosed Only tape interface enabled.
closedopen Only printer interface enabled.
closedclosed Interface disabled.

An inserted jumper is obligatory for the FX-602P to select the destination of the SAVE command either to the file or to the printer.
The FX-702P has separate commands for file saving and printing, so both jumpers can be left open.

Software

download fx702_15.zip - AVR source code